{"id":131,"date":"2015-02-03T16:50:27","date_gmt":"2015-02-04T00:50:27","guid":{"rendered":"http:\/\/research.engineering.ucdavis.edu\/gpa\/?page_id=131"},"modified":"2015-02-17T16:09:57","modified_gmt":"2015-02-18T00:09:57","slug":"statnamic-load-tests","status":"publish","type":"page","link":"https:\/\/research.engineering.ucdavis.edu\/gpa\/foundations-deep\/statnamic-load-tests\/","title":{"rendered":"Statnamic Load Tests"},"content":{"rendered":"<p>Lateral and axial load tests are often performed on pile foundations to assess their load carrying capacity on a site-specific basis. The need to construct a reaction system, usually involving additional piles, is one reason why pile load tests can be expensive. The Statnamic system for pile load testing is a relatively new method that does not require an independent reaction system. For this reason, it can be an economical alternative to conventional loading methods. The following photos are from a demonstration program at the 1997 conference of ASCE&#8217;s GeoInstitute in Logan, Utah.<\/p>\n<div id=\"attachment_771\" style=\"width: 310px\" class=\"wp-caption alignleft\"><a href=\"http:\/\/research.engineering.ucdavis.edu\/gpa\/wp-content\/uploads\/sites\/43\/2015\/02\/Statnamic-P1-Labeled.jpg\"><img loading=\"lazy\" decoding=\"async\" aria-describedby=\"caption-attachment-771\" class=\"wp-image-771 size-medium\" src=\"http:\/\/research.engineering.ucdavis.edu\/gpa\/wp-content\/uploads\/sites\/43\/2015\/02\/Statnamic-P1-Labeled-300x196.jpg\" alt=\"Statnamic P1-Labeled\" width=\"300\" height=\"196\" srcset=\"https:\/\/research.engineering.ucdavis.edu\/gpa\/wp-content\/uploads\/sites\/43\/2015\/02\/Statnamic-P1-Labeled-300x196.jpg 300w, https:\/\/research.engineering.ucdavis.edu\/gpa\/wp-content\/uploads\/sites\/43\/2015\/02\/Statnamic-P1-Labeled-230x150.jpg 230w, https:\/\/research.engineering.ucdavis.edu\/gpa\/wp-content\/uploads\/sites\/43\/2015\/02\/Statnamic-P1-Labeled-150x98.jpg 150w, https:\/\/research.engineering.ucdavis.edu\/gpa\/wp-content\/uploads\/sites\/43\/2015\/02\/Statnamic-P1-Labeled.jpg 749w\" sizes=\"auto, (max-width: 300px) 100vw, 300px\" \/><\/a><p id=\"caption-attachment-771\" class=\"wp-caption-text\">The Statnamic loading system is essentially a rocket engine (yellow body in horizontal orientation) equipped with heavy reaction masses (large steel donuts).<\/p><\/div>\n<div id=\"attachment_772\" style=\"width: 310px\" class=\"wp-caption alignleft\"><a href=\"http:\/\/research.engineering.ucdavis.edu\/gpa\/wp-content\/uploads\/sites\/43\/2015\/02\/Statnamic-P2-Labeled.jpg\"><img loading=\"lazy\" decoding=\"async\" aria-describedby=\"caption-attachment-772\" class=\"wp-image-772 size-medium\" src=\"http:\/\/research.engineering.ucdavis.edu\/gpa\/wp-content\/uploads\/sites\/43\/2015\/02\/Statnamic-P2-Labeled-300x195.jpg\" alt=\"Statnamic P2-Labeled\" width=\"300\" height=\"195\" srcset=\"https:\/\/research.engineering.ucdavis.edu\/gpa\/wp-content\/uploads\/sites\/43\/2015\/02\/Statnamic-P2-Labeled-300x195.jpg 300w, https:\/\/research.engineering.ucdavis.edu\/gpa\/wp-content\/uploads\/sites\/43\/2015\/02\/Statnamic-P2-Labeled-231x150.jpg 231w, https:\/\/research.engineering.ucdavis.edu\/gpa\/wp-content\/uploads\/sites\/43\/2015\/02\/Statnamic-P2-Labeled-150x98.jpg 150w, https:\/\/research.engineering.ucdavis.edu\/gpa\/wp-content\/uploads\/sites\/43\/2015\/02\/Statnamic-P2-Labeled.jpg 749w\" sizes=\"auto, (max-width: 300px) 100vw, 300px\" \/><\/a><p id=\"caption-attachment-772\" class=\"wp-caption-text\">Here the Statnamic system is laid horizontally on a skid in preparation for a lateral load test of a large-diameter CIDH pile.<\/p><\/div>\n<p>&nbsp;<\/p>\n<p>&nbsp;<\/p>\n<p>&nbsp;<\/p>\n<p>&nbsp;<\/p>\n<p>&nbsp;<\/p>\n<p>&nbsp;<\/p>\n<p>&nbsp;<\/p>\n<p>&nbsp;<\/p>\n<div id=\"attachment_773\" style=\"width: 310px\" class=\"wp-caption alignleft\"><a href=\"http:\/\/research.engineering.ucdavis.edu\/gpa\/wp-content\/uploads\/sites\/43\/2015\/02\/Statnamic-P3-Labeled.jpg\"><img loading=\"lazy\" decoding=\"async\" aria-describedby=\"caption-attachment-773\" class=\"wp-image-773 size-medium\" src=\"http:\/\/research.engineering.ucdavis.edu\/gpa\/wp-content\/uploads\/sites\/43\/2015\/02\/Statnamic-P3-Labeled-300x199.jpg\" alt=\"Statnamic P3-Labeled\" width=\"300\" height=\"199\" srcset=\"https:\/\/research.engineering.ucdavis.edu\/gpa\/wp-content\/uploads\/sites\/43\/2015\/02\/Statnamic-P3-Labeled-300x199.jpg 300w, https:\/\/research.engineering.ucdavis.edu\/gpa\/wp-content\/uploads\/sites\/43\/2015\/02\/Statnamic-P3-Labeled-227x150.jpg 227w, https:\/\/research.engineering.ucdavis.edu\/gpa\/wp-content\/uploads\/sites\/43\/2015\/02\/Statnamic-P3-Labeled-150x99.jpg 150w, https:\/\/research.engineering.ucdavis.edu\/gpa\/wp-content\/uploads\/sites\/43\/2015\/02\/Statnamic-P3-Labeled.jpg 745w\" sizes=\"auto, (max-width: 300px) 100vw, 300px\" \/><\/a><p id=\"caption-attachment-773\" class=\"wp-caption-text\">The Statnamic system is connected to the head of the CIDH pile.<\/p><\/div>\n<div id=\"attachment_774\" style=\"width: 209px\" class=\"wp-caption alignleft\"><a href=\"http:\/\/research.engineering.ucdavis.edu\/gpa\/wp-content\/uploads\/sites\/43\/2015\/02\/Statnamic-P4-Labeled.jpg\"><img loading=\"lazy\" decoding=\"async\" aria-describedby=\"caption-attachment-774\" class=\"wp-image-774 size-medium\" src=\"http:\/\/research.engineering.ucdavis.edu\/gpa\/wp-content\/uploads\/sites\/43\/2015\/02\/Statnamic-P4-Labeled-199x300.jpg\" alt=\"Statnamic P4-Labeled\" width=\"199\" height=\"300\" srcset=\"https:\/\/research.engineering.ucdavis.edu\/gpa\/wp-content\/uploads\/sites\/43\/2015\/02\/Statnamic-P4-Labeled-199x300.jpg 199w, https:\/\/research.engineering.ucdavis.edu\/gpa\/wp-content\/uploads\/sites\/43\/2015\/02\/Statnamic-P4-Labeled-99x150.jpg 99w, https:\/\/research.engineering.ucdavis.edu\/gpa\/wp-content\/uploads\/sites\/43\/2015\/02\/Statnamic-P4-Labeled.jpg 489w\" sizes=\"auto, (max-width: 199px) 100vw, 199px\" \/><\/a><p id=\"caption-attachment-774\" class=\"wp-caption-text\">Close-up of the bearing connection being the Statnamic system and CIDH pile.<\/p><\/div>\n<p>&nbsp;<\/p>\n<p>&nbsp;<\/p>\n<p>&nbsp;<\/p>\n<p>&nbsp;<\/p>\n<p>&nbsp;<\/p>\n<p>&nbsp;<\/p>\n<p>&nbsp;<\/p>\n<p>&nbsp;<\/p>\n<p>&nbsp;<\/p>\n<p>&nbsp;<\/p>\n<div id=\"attachment_775\" style=\"width: 310px\" class=\"wp-caption alignleft\"><a href=\"http:\/\/research.engineering.ucdavis.edu\/gpa\/wp-content\/uploads\/sites\/43\/2015\/02\/Statnamic-P5-Labeled.jpg\"><img loading=\"lazy\" decoding=\"async\" aria-describedby=\"caption-attachment-775\" class=\"wp-image-775 size-medium\" src=\"http:\/\/research.engineering.ucdavis.edu\/gpa\/wp-content\/uploads\/sites\/43\/2015\/02\/Statnamic-P5-Labeled-300x200.jpg\" alt=\"Statnamic P5-Labeled\" width=\"300\" height=\"200\" srcset=\"https:\/\/research.engineering.ucdavis.edu\/gpa\/wp-content\/uploads\/sites\/43\/2015\/02\/Statnamic-P5-Labeled-300x200.jpg 300w, https:\/\/research.engineering.ucdavis.edu\/gpa\/wp-content\/uploads\/sites\/43\/2015\/02\/Statnamic-P5-Labeled-225x150.jpg 225w, https:\/\/research.engineering.ucdavis.edu\/gpa\/wp-content\/uploads\/sites\/43\/2015\/02\/Statnamic-P5-Labeled-150x100.jpg 150w, https:\/\/research.engineering.ucdavis.edu\/gpa\/wp-content\/uploads\/sites\/43\/2015\/02\/Statnamic-P5-Labeled.jpg 747w\" sizes=\"auto, (max-width: 300px) 100vw, 300px\" \/><\/a><p id=\"caption-attachment-775\" class=\"wp-caption-text\">The rocket engine is fired, producing a controlled-duration loading pulse. The rocket fire causes the Statnamic system to slide away from the CIDH pile. Records of force and acceleration during the load pulse are used in analyses to back-calculate the lateral loading behavior of the CIDH pile.<\/p><\/div>\n<div id=\"attachment_776\" style=\"width: 208px\" class=\"wp-caption alignleft\"><a href=\"http:\/\/research.engineering.ucdavis.edu\/gpa\/wp-content\/uploads\/sites\/43\/2015\/02\/Statnamic-P6-Labeled.jpg\"><img loading=\"lazy\" decoding=\"async\" aria-describedby=\"caption-attachment-776\" class=\"wp-image-776 size-medium\" src=\"http:\/\/research.engineering.ucdavis.edu\/gpa\/wp-content\/uploads\/sites\/43\/2015\/02\/Statnamic-P6-Labeled-198x300.jpg\" alt=\"Statnamic P6-Labeled\" width=\"198\" height=\"300\" srcset=\"https:\/\/research.engineering.ucdavis.edu\/gpa\/wp-content\/uploads\/sites\/43\/2015\/02\/Statnamic-P6-Labeled-198x300.jpg 198w, https:\/\/research.engineering.ucdavis.edu\/gpa\/wp-content\/uploads\/sites\/43\/2015\/02\/Statnamic-P6-Labeled-99x150.jpg 99w, https:\/\/research.engineering.ucdavis.edu\/gpa\/wp-content\/uploads\/sites\/43\/2015\/02\/Statnamic-P6-Labeled.jpg 483w\" sizes=\"auto, (max-width: 198px) 100vw, 198px\" \/><\/a><p id=\"caption-attachment-776\" class=\"wp-caption-text\">A crane has positioned the Statnamic system vertically over a CIDH pile for an axial load test. A corrugated pipe surrounds the Statnamic system to prevent flying debris from hurting anyone.<\/p><\/div>\n<p>&nbsp;<\/p>\n<p>&nbsp;<\/p>\n<p>&nbsp;<\/p>\n<p>&nbsp;<\/p>\n<p>&nbsp;<\/p>\n<p>&nbsp;<\/p>\n<p>&nbsp;<\/p>\n<p>&nbsp;<\/p>\n<p>&nbsp;<\/p>\n<p>&nbsp;<\/p>\n<p>&nbsp;<\/p>\n<p>&nbsp;<\/p>\n<p>&nbsp;<\/p>\n<div id=\"attachment_777\" style=\"width: 210px\" class=\"wp-caption alignleft\"><a href=\"http:\/\/research.engineering.ucdavis.edu\/gpa\/wp-content\/uploads\/sites\/43\/2015\/02\/Statnamic-P7-Labeled.jpg\"><img loading=\"lazy\" decoding=\"async\" aria-describedby=\"caption-attachment-777\" class=\"wp-image-777 size-medium\" src=\"http:\/\/research.engineering.ucdavis.edu\/gpa\/wp-content\/uploads\/sites\/43\/2015\/02\/Statnamic-P7-Labeled-200x300.jpg\" alt=\"Statnamic P7-Labeled\" width=\"200\" height=\"300\" srcset=\"https:\/\/research.engineering.ucdavis.edu\/gpa\/wp-content\/uploads\/sites\/43\/2015\/02\/Statnamic-P7-Labeled-200x300.jpg 200w, https:\/\/research.engineering.ucdavis.edu\/gpa\/wp-content\/uploads\/sites\/43\/2015\/02\/Statnamic-P7-Labeled-100x150.jpg 100w, https:\/\/research.engineering.ucdavis.edu\/gpa\/wp-content\/uploads\/sites\/43\/2015\/02\/Statnamic-P7-Labeled.jpg 489w\" sizes=\"auto, (max-width: 200px) 100vw, 200px\" \/><\/a><p id=\"caption-attachment-777\" class=\"wp-caption-text\">A cloud of smoke accompanies the firing of the rocket. Again, measurements of axial force and acceleration on the pile head are used in analyses to back-calculate the axial loading behavior of the pile.<\/p><\/div>\n<p>&nbsp;<\/p>\n","protected":false},"excerpt":{"rendered":"<p>Lateral and axial load tests are often performed on pile foundations to assess their load carrying capacity on a site-specific basis. The need to construct a reaction system, usually involving additional piles, is one reason why pile load tests can be expensive. The Statnamic system for pile load testing is  \u2026 <a href=\"https:\/\/research.engineering.ucdavis.edu\/gpa\/foundations-deep\/statnamic-load-tests\/\"> Continue reading <span class=\"meta-nav\">&rarr; <\/span><\/a><\/p>\n","protected":false},"author":69,"featured_media":0,"parent":35,"menu_order":13,"comment_status":"closed","ping_status":"closed","template":"","meta":{"ngg_post_thumbnail":0,"footnotes":""},"class_list":["post-131","page","type-page","status-publish","hentry"],"_links":{"self":[{"href":"https:\/\/research.engineering.ucdavis.edu\/gpa\/wp-json\/wp\/v2\/pages\/131","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/research.engineering.ucdavis.edu\/gpa\/wp-json\/wp\/v2\/pages"}],"about":[{"href":"https:\/\/research.engineering.ucdavis.edu\/gpa\/wp-json\/wp\/v2\/types\/page"}],"author":[{"embeddable":true,"href":"https:\/\/research.engineering.ucdavis.edu\/gpa\/wp-json\/wp\/v2\/users\/69"}],"replies":[{"embeddable":true,"href":"https:\/\/research.engineering.ucdavis.edu\/gpa\/wp-json\/wp\/v2\/comments?post=131"}],"version-history":[{"count":1,"href":"https:\/\/research.engineering.ucdavis.edu\/gpa\/wp-json\/wp\/v2\/pages\/131\/revisions"}],"predecessor-version":[{"id":778,"href":"https:\/\/research.engineering.ucdavis.edu\/gpa\/wp-json\/wp\/v2\/pages\/131\/revisions\/778"}],"up":[{"embeddable":true,"href":"https:\/\/research.engineering.ucdavis.edu\/gpa\/wp-json\/wp\/v2\/pages\/35"}],"wp:attachment":[{"href":"https:\/\/research.engineering.ucdavis.edu\/gpa\/wp-json\/wp\/v2\/media?parent=131"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}