{"id":170,"date":"2015-02-04T08:11:09","date_gmt":"2015-02-04T16:11:09","guid":{"rendered":"http:\/\/research.engineering.ucdavis.edu\/gpa\/?page_id=170"},"modified":"2015-02-11T09:36:45","modified_gmt":"2015-02-11T17:36:45","slug":"flow-slide-diversion-walls","status":"publish","type":"page","link":"https:\/\/research.engineering.ucdavis.edu\/gpa\/landslides\/flow-slide-diversion-walls\/","title":{"rendered":"Flow Slide Diversion Walls"},"content":{"rendered":"<hr \/>\n<p>These slides show a method of reducing the hazard to structures below hillsides in areas where debris flows occur, by constructing walls that divert the flow slides around the structures.<\/p>\n<div id=\"attachment_271\" style=\"width: 310px\" class=\"wp-caption alignleft\"><a href=\"http:\/\/research.engineering.ucdavis.edu\/gpa\/wp-content\/uploads\/sites\/43\/2015\/02\/Debris-Flow-Diversian-Wall-P01.jpg\"><img loading=\"lazy\" decoding=\"async\" aria-describedby=\"caption-attachment-271\" class=\"wp-image-271 size-medium\" src=\"http:\/\/research.engineering.ucdavis.edu\/gpa\/wp-content\/uploads\/sites\/43\/2015\/02\/Debris-Flow-Diversian-Wall-P01-300x241.jpg\" alt=\"This drawing shows the flow slide diversion wall concept. The V-shaped upper end is designed to divert the flows to either side of the structure. (Drawing by Hollingsworth and Kovacs).\" width=\"300\" height=\"241\" srcset=\"https:\/\/research.engineering.ucdavis.edu\/gpa\/wp-content\/uploads\/sites\/43\/2015\/02\/Debris-Flow-Diversian-Wall-P01-300x241.jpg 300w, https:\/\/research.engineering.ucdavis.edu\/gpa\/wp-content\/uploads\/sites\/43\/2015\/02\/Debris-Flow-Diversian-Wall-P01-187x150.jpg 187w, https:\/\/research.engineering.ucdavis.edu\/gpa\/wp-content\/uploads\/sites\/43\/2015\/02\/Debris-Flow-Diversian-Wall-P01-150x121.jpg 150w, https:\/\/research.engineering.ucdavis.edu\/gpa\/wp-content\/uploads\/sites\/43\/2015\/02\/Debris-Flow-Diversian-Wall-P01.jpg 561w\" sizes=\"auto, (max-width: 300px) 100vw, 300px\" \/><\/a><p id=\"caption-attachment-271\" class=\"wp-caption-text\">This drawing shows the flow slide diversion wall concept. The V-shaped upper end is designed to divert the flows to either side of the structure. (Drawing by Hollingsworth and Kovacs).<\/p><\/div>\n<div id=\"attachment_269\" style=\"width: 223px\" class=\"wp-caption alignleft\"><a href=\"http:\/\/research.engineering.ucdavis.edu\/gpa\/wp-content\/uploads\/sites\/43\/2015\/02\/Debris-Flow-Diversian-Wall-P02.jpg\"><img loading=\"lazy\" decoding=\"async\" aria-describedby=\"caption-attachment-269\" class=\"wp-image-269 size-medium\" src=\"http:\/\/research.engineering.ucdavis.edu\/gpa\/wp-content\/uploads\/sites\/43\/2015\/02\/Debris-Flow-Diversian-Wall-P02-213x300.jpg\" alt=\"View of the upper end of a flow slide diversion wall. (Photo by Hollingsworth and Kovacs).\" width=\"213\" height=\"300\" srcset=\"https:\/\/research.engineering.ucdavis.edu\/gpa\/wp-content\/uploads\/sites\/43\/2015\/02\/Debris-Flow-Diversian-Wall-P02-213x300.jpg 213w, https:\/\/research.engineering.ucdavis.edu\/gpa\/wp-content\/uploads\/sites\/43\/2015\/02\/Debris-Flow-Diversian-Wall-P02-106x150.jpg 106w, https:\/\/research.engineering.ucdavis.edu\/gpa\/wp-content\/uploads\/sites\/43\/2015\/02\/Debris-Flow-Diversian-Wall-P02.jpg 498w\" sizes=\"auto, (max-width: 213px) 100vw, 213px\" \/><\/a><p id=\"caption-attachment-269\" class=\"wp-caption-text\">View of the upper end of a flow slide diversion wall. (Photo by Hollingsworth and Kovacs).<\/p><\/div>\n<div id=\"attachment_270\" style=\"width: 310px\" class=\"wp-caption alignleft\"><a href=\"http:\/\/research.engineering.ucdavis.edu\/gpa\/wp-content\/uploads\/sites\/43\/2015\/02\/Debris-Flow-Diversian-Wall-P03.jpg\"><img loading=\"lazy\" decoding=\"async\" aria-describedby=\"caption-attachment-270\" class=\"wp-image-270 size-medium\" src=\"http:\/\/research.engineering.ucdavis.edu\/gpa\/wp-content\/uploads\/sites\/43\/2015\/02\/Debris-Flow-Diversian-Wall-P03-300x203.jpg\" alt=\"View of a wall and the protected house from uphill. (Photo by Hollingsworth and Kovacs).\" width=\"300\" height=\"203\" srcset=\"https:\/\/research.engineering.ucdavis.edu\/gpa\/wp-content\/uploads\/sites\/43\/2015\/02\/Debris-Flow-Diversian-Wall-P03-300x203.jpg 300w, https:\/\/research.engineering.ucdavis.edu\/gpa\/wp-content\/uploads\/sites\/43\/2015\/02\/Debris-Flow-Diversian-Wall-P03-222x150.jpg 222w, https:\/\/research.engineering.ucdavis.edu\/gpa\/wp-content\/uploads\/sites\/43\/2015\/02\/Debris-Flow-Diversian-Wall-P03-150x101.jpg 150w, https:\/\/research.engineering.ucdavis.edu\/gpa\/wp-content\/uploads\/sites\/43\/2015\/02\/Debris-Flow-Diversian-Wall-P03.jpg 716w\" sizes=\"auto, (max-width: 300px) 100vw, 300px\" \/><\/a><p id=\"caption-attachment-270\" class=\"wp-caption-text\">View of a wall and the protected house from uphill. (Photo by Hollingsworth and Kovacs).<\/p><\/div>\n","protected":false},"excerpt":{"rendered":"<p>These slides show a method of reducing the hazard to structures below hillsides in areas where debris flows occur, by constructing walls that divert the flow slides around the structures.<\/p>\n","protected":false},"author":10,"featured_media":0,"parent":38,"menu_order":0,"comment_status":"closed","ping_status":"closed","template":"","meta":{"ngg_post_thumbnail":0,"footnotes":""},"class_list":["post-170","page","type-page","status-publish","hentry"],"_links":{"self":[{"href":"https:\/\/research.engineering.ucdavis.edu\/gpa\/wp-json\/wp\/v2\/pages\/170","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/research.engineering.ucdavis.edu\/gpa\/wp-json\/wp\/v2\/pages"}],"about":[{"href":"https:\/\/research.engineering.ucdavis.edu\/gpa\/wp-json\/wp\/v2\/types\/page"}],"author":[{"embeddable":true,"href":"https:\/\/research.engineering.ucdavis.edu\/gpa\/wp-json\/wp\/v2\/users\/10"}],"replies":[{"embeddable":true,"href":"https:\/\/research.engineering.ucdavis.edu\/gpa\/wp-json\/wp\/v2\/comments?post=170"}],"version-history":[{"count":2,"href":"https:\/\/research.engineering.ucdavis.edu\/gpa\/wp-json\/wp\/v2\/pages\/170\/revisions"}],"predecessor-version":[{"id":272,"href":"https:\/\/research.engineering.ucdavis.edu\/gpa\/wp-json\/wp\/v2\/pages\/170\/revisions\/272"}],"up":[{"embeddable":true,"href":"https:\/\/research.engineering.ucdavis.edu\/gpa\/wp-json\/wp\/v2\/pages\/38"}],"wp:attachment":[{"href":"https:\/\/research.engineering.ucdavis.edu\/gpa\/wp-json\/wp\/v2\/media?parent=170"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}